Data Centers Infrastructure
-
Data Center Space
- IT and colocation space in 3 cubes: 1,000 m²
- Flexible colocation deployments: units, single rack colocation, cages
- Elevated raised floor height: 100 cm
- Available ancillary spaces: offices, equipment storage, and pre-installation rooms
- Meeting rooms available
- Separated and independent technical areas
- Customer shower and changing room
-
Cooling
- Cooling Systems:Modern, highly efficient air conditioning with N+1 redundancy for climate control.
- Energy Management: Weather-dependent and DX-dependent energy management system.
- CRAH Units: Computer Room Air Handler units available for optimal cooling.
- Climate Control:Blown-in air climate control in rows.
- AHUs:Concurrently maintainable Air Handling Units for fresh air pressurization and humidity control.
- Cold Aisle:Designed to support high densities.
- Heat Recovery: Utilizes heat recovery for pre-heating emergency and standby power systems.
- Humidity & Temperature Regulation:Maintains air humidity between 45%-55% and room temperature between 19-21°C.
-
Power
- Power off-site substation delivering 5 MW of power
- Flexible client IT load
- Average power density of 1.5 - 2.0 kW/m²
- Two independent sources of electricity at 5 MW, including a dedicated photovoltaic system
- Two separate UPS systems (A- and B-supply) with N+N redundancy
- Emergency power system with diesel generators, N+N redundancy
- Available UPS: 230V/400V - capacity 1.5 MVA
- UPS redundancy
- 7-12 kW normal power per rack, higher on request
- Total electric output: 1.5 MVA
- Available DC power: 48V
-
Fire Protection
- Automated fire protection system on all levels with fire dampers and smoke extraction
- Very Early Smoke Detection Alarm Systems (VESDA) in the return air path
- Firefighting gas system
- Fire protection absorbing walls and doors
-
Security
- Carrier- and cloud-neutral
- Redundant meet-me-rooms
- Carrier mix from global Tier 1 suppliers to regional suppliers
- Connectivity to major carrier hubs
- Redundant structural cabling infrastructure with diverse paths
- Pre-cabling to support fast cross-connection deployments
- High-performance internet access
- Connectivity between NewTelco data centers for flexible solutions
- NewTelco Neutral Connectivity Exchange platform to connect our clients to major service providers.
-
Connectivity
- IT and colocation space in 3 cubes: 1,000 m²
- Flexible colocation deployments: units, single rack colocation, cages
- Elevated raised floor height: 100 cm
- Available ancillary spaces: offices, equipment storage, and pre-installation rooms
- Meeting rooms available
- Separated and independent technical areas
- Customer shower and changing room
-
Network
- Redundant Layer 1 and Layer 2 network connectivity
- Three dark fiber routes to Frankfurt
- DWD 10G/100G
- Connected to NewTelco Frankfurt Metro Network
- Ethernet Exchange (Neutral Connectivity Exchange platform) for 1G & 10G ports
- DE-CIX enabled node
-
Additional Services
- Consulting services and implementation planning for projects
- Client implementation
- Installation services
- Remote hands services provided by technicians on-site
- Facility services
- DR Workspace
-
Service Level Agreement
- Service Level Agreement
- 99.999% Power Uptime Availability
- Designed in alignment with Tier IVNK 4 requirements for power and telecommunication connectivity
- Precise definition of critical services and availabilities
- Clear commitment to the environment in all aspects